[alerte] Modèle de prévision en dérive #274
Labels
No labels
Compat/Breaking
EC01
EC02
EC03
EC04
EC05
EC06
Kind/BDD
Kind/Back
Kind/Bug
Kind/CICD
Kind/Cloud
Kind/Contenu
Kind/Data
Kind/Documentation
Kind/Enhancement
Kind/Feature
Kind/Front
Kind/IA
Kind/Infra
Kind/Monitoring
Kind/Security
Kind/Testing
Portée/Post-jury
Priority
Critical
Priority
High
Priority
Low
Priority
Medium
Reviewed
Confirmed
Reviewed
Duplicate
Reviewed
Invalid
Reviewed
Won't Fix
Status
Abandoned
Status
Blocked
Status
Need More Info
ops/alerte
No milestone
No project
No assignees
1 participant
Notifications
Due date
No due date set.
Dependencies
No dependencies set
Reference
g2/enervision#274
Loading…
Reference in a new issue
No description provided.
Delete branch "%!s()"
Deleting a branch is permanent. Although the deleted branch may continue to exist for a short time before it actually gets removed, it CANNOT be undone in most cases. Continue?
Alerte Modèle de prévision en dérive
Depuis 2026-09-11T00:36:10Z
Sévérité majeure
Destinataire florian
Les entrées ou l'erreur du modèle promu se sont éloignées de ce qu'il a appris à sa promotion. Il sert toujours.
Seuil verdict = 2 (dérive) pendant 2 h, seuils dans inference/config.py ; ou plus aucune mesure réussie depuis 3 h
Action Lire
journalctlou/var/log/enervision/inference.log: la ligne « DÉRIVE » nomme lequel des trois écarts a déclenché. Ouvrir le tableau de bord « EnerVision — modèle de prévision » (uid enervision-modele), qui trace les trois écarts et l'âge de la dernière mesure. Entrées déplacées seules = le parc a changé de régime, le modèle peut rester bon. Erreur qui monte à entrées stables = le modèle décroche, réentraîner (#36,bin/entrainer.sh). Un réentraînement se décide, il ne se déclenche pas tout seul.Manuel
docs/runbooks/mlflow.mdVoir dans Grafana